Does it rely on load modulation? Extracting and simulating a base station amplifier

A patent infringement matter turned on how the power amplifier in a cellular base station radio frequency (RF) transceiver module actually works. We extracted the circuit from the board, measured every element that mattered, and simulated it. The simulation showed that the amplifier achieves its performance through load modulation.

Case study · Circuit extraction · Patent infringement · Wireless infrastructure

The situation

Matter type
Patent infringement
Product
The power amplifier module in a cellular base station RF transceiver
Question
How the amplifier performs under changing load conditions

The power amplifier is the last stage of a base station transmitter before the duplexer. In 3G and 4G networks, the signal it carries swings widely in amplitude and has to be amplified to 20 to 80 watts. One popular way to keep that efficient is the Doherty amplifier, which combines a main and a peaking stage.

The question in this matter was whether the amplifier in the accused module worked that way, specifically whether its performance came from load modulation.

The challenge

Core difficulty
Load modulation is behavior, not a part you can point to on a board
What it took
An accurate circuit model, built from physical measurements

In a Doherty amplifier, the peaking stage stays off at lower power. As the input rises, it turns on, and the load each stage sees shifts in proportion to the signal. That shift is load modulation. You can’t see it by looking at the board. You have to rebuild the circuit accurately enough to show how it behaves.

What GHB Intellect did

Circuit extraction
Trace dimensions measured under a specially designed microscope; component values measured with inductance-capacitance-resistance (LCR) bridges
Substrate
Dielectric constant of the RF layers calculated with closed-form equations and Avago software
Simulation
Nonlinear harmonic balance simulation of a 100 W device

We extracted the microwave integrated circuit topology of the amplifier module. The controlled-impedance RF traces were measured under a specially designed microscope, and the surface-mount components were removed from the board and measured with LCR bridges.

The board material mattered too. We calculated the substrate’s dielectric constant for the RF portion of the multilayer board and confirmed the materials were ones widely used in RF and power amplifier products.

With the extracted circuit, we ran a nonlinear simulation of a 100 W device using the harmonic balance technique.

Outcomes

Finding
The amplifier achieves its performance through load modulation
Basis
A measured circuit model and nonlinear simulation, not a reading of the datasheet

The simulation clearly showed load modulation as part of the amplifier’s operation, which met the objective of the work.

Figures

The power amplifier board from the base station module
The power amplifier board from the base station module
Calculating trace impedance from measured board dimensions and dielectric
Calculating trace impedance from measured board dimensions and dielectric
The extracted main amplifier, set up for simulation
The extracted main amplifier, set up for simulation
The extracted peaking amplifier, set up for simulation
The extracted peaking amplifier, set up for simulation
Simulated impedance seen by the main amplifier as input power rises
Simulated impedance seen by the main amplifier as input power rises
Simulated impedance seen by the peaking amplifier, showing load modulation
Simulated impedance seen by the peaking amplifier, showing load modulation

Tell us what you need to know

A senior person replies within one business day. All inquiries are confidential.